Secured Trading Service

Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults

Chongqing Blue Jay Technology Co., Ltd
  • Audited Supplier
  • 3 yrs

Contact Supplier

Still deciding? Get samples of $ !
Order Sample

Product Highlights

  • Dual System Monitoring: Monitors DC 0-1000V and AC 0-750V floating systems to ground in real time.
  • EV CAN Bus Interface: Reliably monitors insulation under strong interference and complex driving conditions.
  • IP55 Protection Level: Dust and water resistant design suitable for electric vehicle applications.
  • OEM & ODM Services: Custom logo and function design available with 10+ years manufacturing expertise.
  • IEC & CE Certified: Meets IEC, CE, and ROHS standards with 99.9% qualification rate.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults

Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults pictures & photos
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults pictures & photos
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults pictures & photos
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults pictures & photos
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults pictures & photos
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
  • Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
  • Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
    Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
  • Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
    Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
  • Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
    Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
  • Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
    Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
  • Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
    Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults

Find Similar Products

Product Description

JY1000-EV series insulation monitoring device is used to monitor the insulation resistance of 0~1000Vd.c. DC floating system and 0~750Va.c. AC floating system to ground in real time; measure the insulation fault of equipment shell to ground, high voltage to the shell, etc.

In the DC system, the insulation resistance of the positive pole and the negative pole of the DC system to the ground can be independently measured. In specific electric vehicle applications, CAN bus DC insulation monitor can also be reliably monitored under strong interference or complex driving conditions, such as acceleration/deceleration, braking, and energy recovery.
In the AC system, an Electric Vehicle DC insulation monitor can suppress the interference of voltage high-frequency harmonics, and accurately measure the insulation resistance of the entire AC system to the ground.
 

Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
 

Feature


* DC system: monitor the ground insulation of the 0~1000Vd.c. DC floating system
 
* AC system: Monitor the ground insulation of 0~750Va.c. AC floating system

* Passive equipment: monitor the insulation status between the equipment and the housing or between the equipment and the ground

* When the bus voltage is 0, the insulation resistance of the system to the ground can still be reliably monitored

* Measuring range 0~50 MΩ, when it exceeds 50 MΩ, the default output is 50 MΩ

* Automatic adaptation system Y capacitor CY (CY≤4 μF)

* CAN bus interface

* Built-in high-voltage relay can disconnect the physical connection between the terminal (DC+/DC-) of the insulation monitor and the system under test
 

Specification

Parameter Condition Typical value
Insulation resistance
output mode
JY1000-EV -10D36CAx-x insulation monitor Bus voltage 20~1000 Vd.c. output RISO+ and RISO
Bus voltage 0 ~ 20 Vd.c. Compulsory RISO+ = RISO- = RISO
JY1000-EV -10M36CAx-x insulation monitor Bus voltage 0 ~ 1 000 Vd.c. output RISO
Bus voltage
measurement range
  0 ~ 1 000 Vd.c.
Bus voltage
measurement accuracy
  1%
The power supply range of
auxiliary power supply
  9 ~ 36 Vd.c.
Input power   ≤ 2W
Insulation resistance
measurement range
  0 ~ 50 MΩ
Insulation resistance
measurement accuracy
0~ 100 kΩ, CY≤ 2μF, Bus voltage stability ±12 kΩ
100 kΩ~1 MΩ,CY≤ 2μF, Bus voltage stability ±10 %
1 MΩ~50 MΩ, CY =0μF, Bus voltage stability ±10 %
Insulation resistance
measurement response
time
RISO≥ 500 kΩ, CY =0μF, Bus voltage stability 4 s
RISO<500 kΩ, CY =0μF, Bus voltage stability 5 s
RISO=1 MΩ, CY =1μF, Bus voltage stability 8 s
RISO=1 MΩ, CY =2μF, Bus voltage stability 12 s
DC equivalent internal
resistance
Power on 10.2 MΩ
Amplitude of injection
pulse signal
  ±15 V
Injection pulse signal
frequency
 It is related to the size of the Y capacitor
and insulation resistance
.
self-adaption
High to low-voltage
withstanding voltage
  3 500 Vd.c.
2 500 Va.c.(rms)
CAN to high-voltage
withstanding voltage
  3 500 Vd.c.
2 500 Va.c.(rms)
Working temperature   -40 ºC ~+ 85 ºC
Storage temperature   -40 ºC ~+ 85 ºC
Protection level   IP55
 

Application

 

* Power battery high voltage system of electric vehicle

* Hybrid electric vehicle high voltage system

* Hydrogen energy vehicle high voltage system

* Energy storage system

* Other DC floating system and AC floating system
Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults

Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation FaultsRelated Insulation Monitoring Device for EV chargers and other application

Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults
Blue Jay also provide insulation monitoring solutions for DC charging stations, energy storage systems, photovoltaic systems, DC power grids, and other applications.

Why choose our IMD for your application?
1. comperehensive IMD solutions for different application
There are serveral types of inuslation monitoring devices so you can have multiple choices to find your best IMD solutions.

2. OEM &ODM Service for your special needs
We have specialized in designing and manufacturing insulation monitoring devices for over 10 years. Just provide your needs such as logo and function design, and we can professionally design and manufacture your insulation monitoring device quickly.

3. High-Quality Guaranteed
We strictly select materials, inspect the manufacturing process, and check the product quality, to make our GYID meet the IEC, CE, and ROHS standards. The qualification rate of our insulation monitoring products can reach 99.9%.

 

Company Profile

Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults

Certifications

Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults

Our Service

Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults

FAQ

Jy1000-EV Electric Vehicle DC Insulation Monitoring Device for Positive Negative Insulation Faults

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASI249361". Items marked "verified" are certified.

Watch Video
Watch Video
Chongqing Blue Jay Technology Co., Ltd
Chongqing Blue Jay Technology Co., Ltd
Chongqing Blue Jay Technology Co., Ltd
Chongqing Blue Jay Technology Co., Ltd
Chongqing Blue Jay Technology Co., Ltd
Chongqing Blue Jay Technology Co., Ltd
Chongqing Blue Jay Technology Co., Ltd
Chongqing Blue Jay Technology Co., Ltd

About Our Factory & Business Background

Address
Room 1802, Building 2, No. 88, Jianxin East Road, 400020, Chongqing, China
Terms of Payment
LC, T/T, Western Union
International Commercial Terms(Incoterms)
FOB, CIF, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main Products
Panel Meter, Energy Meter, Multifunction Power Meter, Protection Relay, Electrical Transducer, Thermostat, Smart Meter, Temperature Sensor, Energy Metering, Low Voltages

Our Industry Experience & Global Business Record

Export Year
2009-05-03
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Western Europe

FAQ

What voltage systems does this device monitor?
It monitors DC floating systems from 0 to 1000V and AC floating systems from 0 to 750V.
Can it work in electric vehicles with high interference?
Yes, the CAN bus interface ensures reliable monitoring during acceleration, braking, and energy recovery.
Does it support custom branding or design?
Yes, we offer OEM and ODM services for logo and function design based on your needs.
What certifications does the product have?
The product meets IEC, CE, and ROHS standards with a 99.9% qualification rate.
What is the lead time for orders?
Peak season lead time is one month, while off-season lead time is within 15 workdays.
What payment terms are accepted?
We accept LC, T/T, and Western Union for payments.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now