APM-96J Multi-Function Power Monitor is a high-end multifunction power meter. It is the ideal choice for monitoring and measuring power systems.
It can measure all of the power parameters in the power grid:
Current, Voltage, Frequency, Active power, Reactive power, |
Apparent power, Energy (Active/Reactive), Power factor, Current harmonics 2~31 times, Voltage harmonics 2~31 times, |
Voltage and current THD%, Harmonics factor, Voltage crest factor, Current K-factor, Multi- tariffs ratio. |
With optional expansion modules, it can also transmit the parameter into 2*Relay output (2DO) and 4*Switch input (4DI), 2*Analog output (2AO). For transformers, generators, capacitor banks, and motors of the distributed detection, automatic control system, on-line monitoring display. BJ-194J provides 50 lists of event logging, real-time saving DI/DO acted events.
It can replace the traditional analog or many digital measurement instruments (such as ammeter, voltmeter, power meter, power factor meter, frequency meter, etc.) with the advantages of improving system reliability, making the on-site wiring convenient, and reducing system cost.
With a serial port, APM-96J can connect with a PC; and use Modbus to set programming and read the data. You can set up a monitoring system with the IPC and central software based on these power meters.
Accuracy standards
Parameter |
Accuracy |
A phase |
B phase |
C phase |
All |
Voltage Current Active Power Reactive Power Apparent power Power Factor Active Energy Reactive Energy Frequency |
0.2 0.2 0.5s 0.5s 0.5s 0.5s 0.5 2.0 0.05 |
V1 A1 W1 var1 VA1 PF1
|
V2 A2 W2 var2 VA2 PF2
|
V3 A3 W3 var3 VA3 PF3
|
W var VA PF Wh varh Hz |
·Measurement accuracy class 0.2
·Current measuring .../5 or .../1 A
·Backlit LCD
·Universal series power supply (85-265VAC/DC)
·ITF Technology: galvanic insulation protection inputs outputs
·Record and read tariffs ratio, Up to 3 months
· Various advanced electrical parameters can display the status of the power grid on the spot (Max demand/unbalance/crest factor/K factor...)
·Provide max 50 lists SOE record function
·With RS-485 Modbus/RTU Communications
·With 2-channel Pulse Output (PO) for active energy & reactive energy counting
·Optional 2-channel Analog Output (AO)
·Optional 4 channel Digital Input (DI) and 2 channel Digital Output (DO)
Power Supply | AC / DC 80-265V, 45-65Hz DC 20-60V (Optional) Burned < 10VA |
Current Measurement | …/ 1A or …/5 A Burned < 0.1W |
Voltage Measurement | Direct measurement 18~277V ac (L-N) PT secondary …/100Vac Burned < 0.1W |
Frequency Measurement | 45~65Hz Resolution 0.01Hz |
Accuracy | U & I - 0.2% ; P &Q - 0.5% Frequency - 0.1% Active Energy - 0.5s class Reactive Energy - 2.0s class |
Communication Port | RS485 (2/3 wires half duplex) Modbus RTU mode |
Pulse Outputs | 2-channel Coupler relay |
Analog Outputs (Optional) | Max 3 channel Isolated 0 / 4 … 20 mA |