• RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System
  • RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System
  • RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System
  • RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System
  • RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System
  • RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System

RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System

After-sales Service: 1year
Warranty: 1year
Display: Digital
Samples:
US$ 80/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System pictures & photos
RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System
US $50-100 / Piece
Min. Order: 1 Piece
Gold Member Since 2024

Suppliers with verified business licenses

Secured Trading Service
Chongqing, China
Years of Export Experience
The export experience of the supplier is more than 10 years
Low MOQ
The MOQ for the supplier's products is 1
ODM Services
The supplier provides ODM services
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (18)
  • Overview
  • Feature
  • Specification
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
DCEM-4MS
Installation
Indirect Connected
Usage
Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment
Three-phase Four-wire
Theory
Electronic Meter
Power Meter Connection
CT
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Transport Package
Carton
Specification
10*10*10
Trademark
Blue Jay
Origin
China
Production Capacity
1000 Piece/Pieces Per Day

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
0.650kg

Product Description

DCEM-4MS Dual-channel DC energy meter is a highly integrated product for DC parameter measurement. When used with a shunt or external Hall sensor, it can accurately measure 1-2 channels DC voltages and 1-2 channels DC currents (with direction), power, total electricity, each single-circuit electricity, and other electrical parameters, and can be equipped with optional DI modules.

DCEM-4MS has RS485 and supports MODBUS-RTU communication protocol, which can upload the collected data and equipment status. DCEM-4MS is widely used in electric power, communications, railways, transportation, environmental protection, steel, and other industries to monitor the current and power consumption of DC equipment.
RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System

Function

  • Measurement and calculation functions such as DC voltage, current, power, and forward and reverse electric energy.
  • Multi-rate electric energy metering function
  • Maximum demand measurement and demand time recording
  • Maximum value record: single-phase voltage, current, power maximum and minimum values, and occurrence time
  • Time-stamped event recording
  • power freeze
  • Supports RS485 interface MODBUS-RTU communication protocol, and one more RS485 port can be selected
  • 2-way switch input monitoring, 2-way relay output (optional)
  • Supports second DC voltage and current input (optional)

Feature

  • Various anti-interference measures.
  • Convenient and flexible system wiring.
  • Easy to install, 35mm standard DIN rail installation.
  • Powerful data collection and processing capabilities.
  • Intuitive Large-size LCD screen real-time measurement information.
  • High security and good reliability
    A variety of anti-interference measures have been adopted during the design process to ensure stable operation in the power system environment. The electrostatic discharge immunity meets level 4; the electrical fast transient burst immunity meets level 4; the high voltage impact immunity meets level 4; the surge immunity meets level 3; the panel protection level meets IP54, and the shell protection level meets IP20.

Specification

Performance Parameter
Enter Measurement Display Distribution network DC
Voltage Rating 0-1000V
Overload  Measurement: 1.2 times Instantaneous: 10 times/1s
Impedance >1 kΩ/V
  Rating DC Shunt:0-75mV
current Hall current sensor:5A,20A,50A,100A,200A,300A,400A,500A optional
  Overload Measurement: 1.2 times Instantaneous: 2 times/10s
  Impedance <100mΩ
Accuracy level Class 1 or 0.5
Clock (optional): The daily error is less than 0.5 seconds
Display Segment LCD display
Power supply range AC/DC85V~265V
power consumption ≤4VA
Output Digital interface RS-485, MODBUS-RTU protocol (optional 2-Channels RS-458)
Pulse output Optional 1 channel active electric energy pulse output,1 channel second pulse output
DI input (optional) 2 DI, dry contact mode
Ri<500Ω turns on, Ri>100kΩ turns off
DI output (optional) 2 DO relay
relay contact capacity: 5A/250V AC; 5A/30V DC
Environment Working environment -25~55°C Altitude ≤2000m,98%RH, no condensation, no corrosive gas
Storage environment -30~75°C
Safety Withstand voltage Input and power supply>4kV; input and output>4kV.power supply and output>4Kv.
Insulation Power supply to shell > 5MΩ

Company Profile

RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar SystemRS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar SystemRS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System

FAQ

RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System pictures & photos
RS485 Kwh Watt Hour Dual Circuits DC Electric Energy Meter with Hall Sensor or DC Shunt for EV Charger Solar System
US $50-100 / Piece
Min. Order: 1 Piece
Gold Member Since 2024

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
>2000 square meters