Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System

Product Details
Customization: Available
Theory: Electromagnetic Relay
Usage: Car Relay, Household Appliances Relay, Communication Relay, Lathe Relay
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
3D Software Design
The supplier provides 3D software design services
Customization from Designs
The supplier provides design based customization services
to see all verified strength labels (18)
  • Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System
  • Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System
  • Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System
  • Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System
  • Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System
  • Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System
Find Similar Products
  • Overview
  • Feature
  • Specification
  • Application
  • Company Profile
  • Certifications
  • Our Service
  • FAQ
Overview

Basic Info.

Model NO.
BIM-CH1
Phase
3
Electricity Type
Dc
Number of Pole
3
Load
Medium Power Relay
Protective Characteristics
Enclosed Relay
Action Principle
Electronic Type
Size
Miniature
Type
Electric Parameter Relay
DC Voltage Range
0V~1000V
off-Line Pressure Test
<2mA
Standard
IEC 61851-23 (2014-03):2014-11
Humidity
85%
Transport Package
Carton
Specification
10*10cm
Trademark
Blue jay
Origin
China
Production Capacity
1000PCS Per Month

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
1.000kg

Product Description

The BIM-CH1 monitors the insulation resistance of DC systems (IT systems) devices up to DC 0- 1000V. BIM-CH1 has insulation monitoring start and stop functions. After insulation monitoring is turned on, it can real time monitor the insulation resistance of the positive and negative poles to the ground. The monitoring results are not affected by DC voltage fluctuations and the symmetry of the insulation resistance of the positive and negative poles.

BIM-CH1 is equipped with RS485 /Modbus communication, which can remotely monitor the system status. BIM-CH1 uses two working principles for monitoring: unbalanced bridge method and balanced bridge method, allowing continuous monitoring of voltage and resistance values. Optional current sensors or temperature sensors can be configured for current and temperature measurements.
Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System
Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System
Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System
 

Feature

  1. Adaptive capacitance to ground;
  2. Widely insulation monitoring range (100V~1000VDC);
  3. Monitoring the insulation resistance for unearthed DC systems: 1KΩ~10MΩ;
  4. Measured value indication via a multi-functional LCD display;
  5. Automatic device self-test with disconnection monitoring;
  6. DC voltage reverse connection alarm function;
  7. RS485 communication, MODBUS RTU protocol;
  8. Selectable N/C or N/O relay operation;
  9. Password protection to prevent unauthorized parameter changes;
  10. Optional temperature sensor for system temperature measurement.

Specification

Parameter Value
Power supply 10-30VDC, Power 3w
DC voltage range 100V~1000V
DC voltage
measurement accuracy
≤2V+0.3%
Insulation resistance
measurement range
1KΩ~10MΩ
(DC System voltage:100V~1000V)
Insulation monitoring accuracy
((When :DC voltage:100V-1000V)
CY range Resistance range Accuracy
0~0.8μF ≤60kΩ ≤3kΩ
60kΩ<R≤1MΩ ≤5%
0.8μF ~3μF ≤60kΩ ≤6kΩ
60kΩ<R≤1MΩ ≤20%
Insulation resistance value
update time after turning on
After insulation monitoring is turned on, the time until the effective resistance value can be read for the first time 0.7s~2s
Insulation resistance value
update time
Switch the insulation resistance until the module can read the switched insulation resistance value. 0.5s~3s
Insulation monitoring function switching times 50*105 times
Off-line pressure test <2mA
Standard IEC 61557-8:2018
Humidity 85%
Storage temperature - 40°C ~125°C
Operating temperature - 40°C ~75°C

Application

Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System

Company Profile

 

Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System

Certifications

Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System

Our Service

Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System

FAQ

Bim-CH1 EV Charger Battery Multi-Channel Temperature Ground Fault Insulation Monitoring IMD Electrical Insulation Monitoring Device for AC DC System

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier