The APM-96Q Multi-Function Power Meter is a sophisticated and intelligent device for medium and low-voltage power systems. This advanced meter accurately measures and calculates energy consumption, providing valuable insights into power usage and system performance.
1. Electricity Metering
APM-96Q can simultaneously measure all power parameters in the power grid-the detailed electricity metering parameters are in the following table.
Parameter | Symbol | A-phase | B-phase | C-phase | Total |
Single phase voltage | V | Yes | Yes | Yes | No |
Phase-line voltage | V | Yes | Yes | Yes | No |
Phase-phase voltage | V | Yes | Yes | Yes | No |
Current | A | Yes | Yes | Yes | No |
Frequency | Hz | No | No | No | Yes |
Power factor | Cos Φ | Yes | Yes | Yes | Yes |
Active power | W | Yes | Yes | Yes | Yes |
Reactive power | Var | Yes | Yes | Yes | Yes |
Apparent power | VA | Yes | Yes | Yes | Yes |
Active energy | Wh | Yes | Yes | Yes | Yes |
Reactive energy | Varh | Yes | Yes | Yes | Yes |
Multi-tariffs energy record | Wh | No | No | No | Yes |
Max demand (W No var No VA) | MAX | No | No | No | Yes |
Voltage No frequency deviation | V | Yes | Yes | Yes | No |
Voltage No current unbalance | % | No | No | No | Yes |
THD & Harmonic (2~63th) | THD | Yes | Yes | Yes | Yes |
Parameter | Accuracy | A phase | B phase | C phase | All |
Voltage | 0.5s | V1 | V2 | V3 | / |
Current | 0.5s | A1 | A2 | A3 | / |
Active power | 0.5s | W1 | W2 | W3 | W |
Reactive power | 1 | var1 | var2 | var3 | var |
Apparent power | 0.5s | VA1 | VA2 | VA3 | VA |
Power factor | 0.5s | PF1 | PF2 | PF3 | PF |
Active energy | 0.5s | / | / | / | Wh |
Reactive energy | 1 | / | / | / | varh |
Frequency | 0.02 | / | / | / | Hz |
Working power | AC/DC 85-265V, (DC 48V or AC 380V customized) 45-65Hz Consumption: 4W |
Reference standard | Basic electricity: IEC 61557-12:2016 Active energy: IEC 62053-21:2018 Reactive energy: IEC 62053-23:2018 |
Voltage | AC100V, 220V, 380V type 96mm and 42mm support AC690V, please specify when ordering). |
Current | AC 1A/5A (please specify when ordering) |
Frequency | 40~65Hz, accuracy class: ±0.02Hz |
Current overload | Measurement: 1.2 times Instantaneous: 2 times/10s |
Voltage overload | Measurement: 1.2 times Instantaneous: 2 times/10s |
SOE | 50 lists (10 lists DI/DO SOE; 40 lists Alarm SOE) |
Multi-tariff | Multi-tariff 4 sets rates |
Communication | RS485, Modbus-RTU or Ethernet, Modbus-TCP/IP |
Pulse output | 2 Channel |
DI | 4 DI, dry contact, Ri<500Ω turns on, Ri>100kΩ turns off |
DO | 2 DO, Relay contact capacity: 5A@250V AC; 5A@30V DC |
AO | 3 AO, Current 4~20mA, load <390Ω, Voltage 0~10V, load >100kΩ |
Load | Voltage: <0.1VA / phase (rated 220V) Current: <0.4VA / phase (rated 5A) |
Safety | 2kV AC RMS 1 minute, between input / output / case / power supply Input, output and power supply to the chassis ≥100MΩ |