Customization: | Available |
---|---|
Theory: | Electromagnetic Relay |
Usage: | Insulation Monitor |
Still deciding? Get samples of US$ 100/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
GYID series ground fault relay is used for real-time monitoring of the insulation resistance between the high voltage components (0~1000Vdc) and the chassis (earth) of the power battery pack (pure electric or hybrid) power supply system. The measurement technology used in this product can monitor the insulation faults on the DC side, the AC side, and the motor side; The ground fault detection DC system can simultaneously monitor the positive and negative asymmetric insulation faults and symmetrical insulation faults; it can monitor the internal insulation faults of the battery pack and locate the fault point; It can monitor in the case of short circuit on the high-voltage DC side; in the case of high-intensity interference, such as acceleration, deceleration, and energy recovery, it can also reliably monitor insulation resistance.
Accuracy |
1% |
Measurement range |
0-1000VDC |
0-750VAC |
|
Power supply |
9-36VDC |
Input power |
≤ 2W |
Insulation resistance |
0 ~ 50 MΩ (Default is 50 MΩ when over 50 MΩ) |
Insulation accuracy |
±12 kΩ (@ 0~100 kΩ, CY≤ 2μF) |
±10 % (@100 kΩ~1 MΩ, CY≤ 2μF) |
|
±10 % (@1MΩ~50MΩ, CY≤ 2μF) |
|
Response time |
4s (@RISO≥ 500 kΩ, CY =0μF) |
5s (@RISO<500 kΩ, CY =0μF) |
|
8s (@RISO=1MΩ, CY =1μF) |
|
12s (@RISO=1MΩ, CY =2μF) |
|
High voltage input resistance |
Positive 5 MΩ,Negative 1 MΩ to ground (@Internal high voltage relay closed) |
Positive& negative poles to ground over 500 MΩ (@Internal high voltage open) |
|
Pulse signal amplitude |
±15 V |
Pulse signal frequency |
Adaptive |
Isolation withstand voltage |
3500VDC, 2500VAC (RMS) |
Operating temperature |
-40 ~+85 |
Storage temperature |
-40 ~+85 |
IP protection |
IP 55 |
Weight |
0.5kg (Aluminum package) |