JY1000-EV series insulation monitoring device is used to monitor the insulation resistance of 0~1000Vd.c. DC floating system and 0~750Va.c. AC floating system to ground in real time; measure the insulation fault of equipment shell to ground, high voltage to the shell, etc.
In the DC system, the insulation resistance of the positive pole and the negative pole of the DC system to the ground can be independently measured. In specific electric vehicle applications, CAN bus DC insulation monitor can also be reliably monitored under strong interference or complex driving conditions, such as acceleration/deceleration, braking, and energy recovery.
In the AC system, an Electric Vehicle DC insulation monitor can suppress the interference of voltage high-frequency harmonics, and accurately measure the insulation resistance of the entire AC system to the ground.
Parameter | Condition | Typical value | |
Insulation resistance output mode |
JY1000-EV -10D36CAx-x insulation monitor | Bus voltage 20~1000 Vd.c. | output RISO+ and RISO |
Bus voltage 0 ~ 20 Vd.c. | Compulsory RISO+ = RISO- = RISO | ||
JY1000-EV -10M36CAx-x insulation monitor | Bus voltage 0 ~ 1 000 Vd.c. | output RISO | |
Bus voltage measurement range |
0 ~ 1 000 Vd.c. | ||
Bus voltage measurement accuracy |
1% | ||
The power supply range of auxiliary power supply |
9 ~ 36 Vd.c. | ||
Input power | ≤ 2W | ||
Insulation resistance measurement range |
0 ~ 50 MΩ | ||
Insulation resistance measurement accuracy |
0~ 100 kΩ, CY≤ 2μF, Bus voltage stability | ±12 kΩ | |
100 kΩ~1 MΩ,CY≤ 2μF, Bus voltage stability | ±10 % | ||
1 MΩ~50 MΩ, CY =0μF, Bus voltage stability | ±10 % | ||
Insulation resistance measurement response time |
RISO≥ 500 kΩ, CY =0μF, Bus voltage stability | 4 s | |
RISO<500 kΩ, CY =0μF, Bus voltage stability | 5 s | ||
RISO=1 MΩ, CY =1μF, Bus voltage stability | 8 s | ||
RISO=1 MΩ, CY =2μF, Bus voltage stability | 12 s | ||
DC equivalent internal resistance |
Power on | 10.2 MΩ | |
Amplitude of injection pulse signal |
±15 V | ||
Injection pulse signal frequency |
It is related to the size of the Y capacitor and insulation resistance . |
self-adaption | |
High to low-voltage withstanding voltage |
3 500 Vd.c. 2 500 Va.c.(rms) |
||
CAN to high-voltage withstanding voltage |
3 500 Vd.c. 2 500 Va.c.(rms) |
||
Working temperature | -40 ºC ~+ 85 ºC | ||
Storage temperature | -40 ºC ~+ 85 ºC | ||
Protection level | IP55 |