• 100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus
  • 100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus
  • 100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus
  • 100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus
  • 100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus
  • 100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus

100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus

After-sales Service: 1 Year
Warranty: 1 Year
Display: Digital
Samples:
US$ 200/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus pictures & photos
100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus
US $50-200 / pieces
Min. Order: 1 pieces
Gold Member Since 2024

Suppliers with verified business licenses

Secured Trading Service
Chongqing, China
Years of Export Experience
The export experience of the supplier is more than 10 years
Low MOQ
The MOQ for the supplier's products is 1
ODM Services
The supplier provides ODM services
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (18)
  • Overview
  • Feature
  • Specification
  • Application
  • Company Profile
  • Certifications
  • Our Service
  • FAQ
Overview

Basic Info.

Model NO.
DCEM-3MS
Installation
Direct Connected
Usage
Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter
Electric Equipment
Three-phase Three-wire
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Operating Temperature
-20~55c
Measuring Energy Range
0-999999
Phase
Three Phase
Display Type
Analog and Digital
Dimensions
104mmx50mmx63mm
Accuracy Class
0.5
Output Voltage
220V
Transport Package
Carton
Specification
10*10cm
Trademark
BlueJay
Origin
Chongqing, China

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
0.650kg

Product Description

DCEM-3MS DC Energy Meter With RS485 is a combined DC power measurement terminal, which is a highly integrated product for DC parameter measurement applications. It can accurately measure 1 DC voltage and 1 DC current (with direction) with an external shunt, power, total electricity, each single-way electricity, and other electrical parameters, and can be equipped with a switch output.
 

This Multifunction DC energy meter has an RS485 interface, supports the MODBUS-RTU communication protocol, and can upload the data collected by the measurement and the status of the equipment. The device can be widely used in electric power, communication, railway, transportation, environmental protection, petrochemical, steel, and other industries to monitor the current and power consumption of DC equipment.

100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus

Feature

 
* High precision measurement
* Small size, easy installation
* Standard 35mm rail installation
* High security: high isolation voltage
* Single-phase wiring
* way independent shunt access, segment LCD display
* Powerful data acquisition and processing functions
* A variety of anti-interference measures, high security
* LCD screen display intuitive, easy to operate

 

Specification

Voltage input
 
Rated value
0-1000V
Overload
Measurement: 1.2 times Instantaneous: 2 times/10s
Impedance
>1 kΩ/V
Accuracy
Accuracy grade: 0.5%FS
Current input
 
Rated value
Shunt: conventional 75mV, others need to be specified separately
Overload
Measurement: 1.2 times Instantaneous: 10 times/1s
Impedance
<100mΩ
Accuracy
Accuracy grade: 0.5%FS
Power supply
 
The scope of work
AC/DC85V~265V
Power consumption
≤4VA
Output
 
Digital interface
RS-485,MODBUS-RTU
Pulse output
Optional 1 channel active energy pulse output
Environment
 
Working environment
-25~55,Altitude ≤2000m, 98%RH, no condensation, no corrosive gas
Storage environment
-30~75
Safety
 
Pressure resistance
Input and Power>2kV; Input and Output>2kV; Power and Output>2kV
Insulation
Input, output, power supply > 5MΩ to the chassis
Others
 
Electric energy
Active energy level 1
Display
LCD with white backlit
Power
Accuracy: 0.5%FS
100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus
 

Application


100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus

Company Profile


100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus

Certifications


100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus

Our Service


100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus

FAQ


100A Shunt DC Meter Max Max. 1000V DC Energy Meter with RS485 Modubus
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now