The APM-96Q Multi-Function Power Meter is a sophisticated and intelligent device for medium and low-voltage power systems. This advanced meter accurately measures and calculates energy consumption, providing valuable insights into power usage and system performance.
1. Electricity Metering
APM-96Q can simultaneously measure all power parameters in the power grid-the detailed electricity metering parameters are in the following table.
| Parameter | Symbol | A-phase | B-phase | C-phase | Total |
| Single phase voltage | V | Yes | Yes | Yes | No |
| Phase-line voltage | V | Yes | Yes | Yes | No |
| Phase-phase voltage | V | Yes | Yes | Yes | No |
| Current | A | Yes | Yes | Yes | No |
| Frequency | Hz | No | No | No | Yes |
| Power factor | Cos Φ | Yes | Yes | Yes | Yes |
| Active power | W | Yes | Yes | Yes | Yes |
| Reactive power | Var | Yes | Yes | Yes | Yes |
| Apparent power | VA | Yes | Yes | Yes | Yes |
| Active energy | Wh | Yes | Yes | Yes | Yes |
| Reactive energy | Varh | Yes | Yes | Yes | Yes |
| Multi-tariffs energy record | Wh | No | No | No | Yes |
| Max demand (W No var No VA) | MAX | No | No | No | Yes |
| Voltage No frequency deviation | V | Yes | Yes | Yes | No |
| Voltage No current unbalance | % | No | No | No | Yes |
| THD & Harmonic (2~63th) | THD | Yes | Yes | Yes | Yes |
| Parameter | Accuracy | A phase | B phase | C phase | All |
| Voltage | 0.5s | V1 | V2 | V3 | / |
| Current | 0.5s | A1 | A2 | A3 | / |
| Active power | 0.5s | W1 | W2 | W3 | W |
| Reactive power | 1 | var1 | var2 | var3 | var |
| Apparent power | 0.5s | VA1 | VA2 | VA3 | VA |
| Power factor | 0.5s | PF1 | PF2 | PF3 | PF |
| Active energy | 0.5s | / | / | / | Wh |
| Reactive energy | 1 | / | / | / | varh |
| Frequency | 0.02 | / | / | / | Hz |
| Working power | AC/DC 85-265V, (DC 48V or AC 380V customized) 45-65Hz Consumption: 4W |
| Reference standard | Basic electricity: IEC 61557-12:2016 Active energy: IEC 62053-21:2018 Reactive energy: IEC 62053-23:2018 |
| Voltage | AC100V, 220V, 380V type 96mm and 42mm support AC690V, please specify when ordering). |
| Current | AC 1A/5A (please specify when ordering) |
| Frequency | 40~65Hz, accuracy class: ±0.02Hz |
| Current overload | Measurement: 1.2 times Instantaneous: 2 times/10s |
| Voltage overload | Measurement: 1.2 times Instantaneous: 2 times/10s |
| SOE | 50 lists (10 lists DI/DO SOE; 40 lists Alarm SOE) |
| Multi-tariff | Multi-tariff 4 sets rates |
| Communication | RS485, Modbus-RTU or Ethernet, Modbus-TCP/IP |
| Pulse output | 2 Channel |
| DI | 4 DI, dry contact, Ri<500Ω turns on, Ri>100kΩ turns off |
| DO | 2 DO, Relay contact capacity: 5A@250V AC; 5A@30V DC |
| AO | 3 AO, Current 4~20mA, load <390Ω, Voltage 0~10V, load >100kΩ |
| Load | Voltage: <0.1VA / phase (rated 220V) Current: <0.4VA / phase (rated 5A) |
| Safety | 2kV AC RMS 1 minute, between input / output / case / power supply Input, output and power supply to the chassis ≥100MΩ |