24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System

Product Details
Customization: Available
Theory: Electromagnetic Relay
Phase: 3
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
3D Software Design
The supplier provides 3D software design services
Customization from Designs
The supplier provides design based customization services
to see all verified strength labels (18)
  • 24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System
  • 24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System
  • 24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System
  • 24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System
  • 24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System
  • 24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System
Find Similar Products
  • Overview
  • Product Description
  • Feature
  • Application
  • Specification
  • Wiring Diagram
  • Dimension
  • Company Profile
Overview

Basic Info.

Model NO.
ELR-4MD
Electricity Type
AC DC
Number of Pole
3
Load
Medium Power Relay
Protective Characteristics
Enclosed Relay
Action Principle
Electromagnetic Type
Size
78*90*60 mm
Type
Electric Parameter Relay
Reset Type
Locally, Remote and Automatically
Measurement
a-Type Residual Current
Communication
RS485
Frequency
50/60Hz
Transport Package
Carton
Specification
10*10cm
Trademark
Blue Jay
Origin
China
Production Capacity
1000PCS Per Month

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
0.650kg

Product Description

 

Product Description

The ELR-4MA  AC Earth Leakage Relay is an advanced protection device designed to enhance the safety and reliability of electrical systems. With a residual current transformer (RCT), it continuously monitors the residual current in the busbars or branches of the system. When the residual current exceeds the preset threshold, the relay promptly outputs an alarm signal, ensuring early detection of potential faults.

Equipped with an alarm function, the ELR-4MA ensures that alarm signals remain clearly indicated until the reset signal, facilitating easy fault diagnosis and troubleshooting. ELR-4MA is critical for preventing equipment damage, minimizing downtime, and safeguarding personnel against electrical hazards.

Feature

  1. Isolated auxiliary power supply; 
  2. 2XSPDT relay outputs;
  3. Remote test/rest connections;
  4. Standard 35mm din rail mounting;
  5. RS485 Modbus communication;
  6. Type A residual current measurement;
  7. Rated residual action current can be set ;
  8. Limit non-driving time can be set ;
  9. Two sets of relay outputs (settable) ;
  10. The fault alarm of transformer can be set; Warning value can be set ;

Application

  1. Smart grid system;
  2. Medium and low voltage systems;
  3. Commercial and residential buildings;
  4. Utilities and power distribution systems;
  5. Motor control panels and switchboards;
  6. Distribution line grounding fault protection
  7. General grounding fault protection load
  8. Direct grounding protection
  9. High resistance grounding fault protection grounding

Specification

Parameter Value
Auxiliary power supply 85-265Vac/dc
Power consumption ≤4VA
Frequency 50/60Hz, Accuracy ±0.01Hz
Leakage current alarm threshold 6mA-60A, can set as need.
Time delay 50ms-10sec, can set as need.
Communication RS-485 MODBUS-RTU
Display LCD with backlit
Withstand voltage 2.5KV 1min
Insulation Input, output, power supply to shell >5MΩ
Storage environment -40~70°C
Working environment -25~55°C Altitude ≤2500m,
0~95%RH, non-condensing, non-corrosive gas

 

Wiring Diagram

24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System



 

Dimension

24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System
24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System
 

Company Profile


24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System24V DIN Rail Overcurrent Earth Fault Protection AC DC Earth Leakage Relay for Single Phase 3 Phase Power System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier