JY1000-AL is a DC-to-Ground insulation monitoring module based on the principle of unbalanced bridge, which has monitoring and protection functions in one. It can monitor the insulation resistance value of the positive and negative poles of the DC floating system to the ground, ranging from 1KΩ~10 MΩ; at the same time, it can also detect the DC voltage value, ranging from 100V to 1000V
Parameter | Value | ||
Power supply | 9-30VDC, Power 3W | ||
DC voltage range | 100V~1000V | ||
DC voltage measurement accuracy |
≤2V+0.3% | ||
Insulation resistance measurement range |
1KΩ~10 MΩ (DC System voltage:100V~1000V) |
||
Insulation monitoring accuracy ((When :DC voltage:100V-1000V) |
CY range | Resistance range | Accuracy |
0~0.8μF | ≤60kΩ | ≤3kΩ | |
60kΩ<R≤1MΩ | ≤5% | ||
0.8μF ~3μF | ≤60kΩ | ≤6kΩ | |
60kΩ<R≤1MΩ | ≤20% | ||
Off-line pressure test | <2mA | ||
Maximum relay switching voltage | 400VAC/600VDC | ||
Maximum relay switching current | 4A | ||
Relay contact resistance | <100mΩ | ||
Relay insulation resistance | 1000MΩ | ||
Standard | IEC 61851-23 (2014-03):2014-11 | ||
Humidity | ≤90% | ||
Storage temperature | - 55°C ~90°C | ||
Operating temperature | - 40°C ~75°C |