Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems

Product Details
Customization: Available
Theory: Electromagnetic Relay
Usage: Car Relay, Household Appliances Relay, Communication Relay, Lathe Relay
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
3D Software Design
The supplier provides 3D software design services
Customization from Designs
The supplier provides design based customization services
to see all verified strength labels (18)
  • Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems
  • Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems
  • Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems
  • Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems
  • Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems
  • Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems
Find Similar Products
  • Overview
  • Feature
  • Specification
  • Application
  • Company Profile
  • Certifications
  • Our Service
  • FAQ
Overview

Basic Info.

Model NO.
BIM-CH1
Phase
3
Electricity Type
Dc
Number of Pole
3
Load
Medium Power Relay
Protective Characteristics
Enclosed Relay
Action Principle
Electronic Type
Size
Miniature
Type
Electric Parameter Relay
DC Voltage Range
0V~1000V
off-Line Pressure Test
<2mA
Standard
IEC 61851-23 (2014-03):2014-11
Humidity
85%
Insulation Resistance Measurement Range
1KΩ~10mΩ
Transport Package
Carton
Specification
10*10cm
Trademark
Blue jay
Origin
China
Production Capacity
1000PCS Per Month

Product Description

The BIM-CH1 monitors the insulation resistance of DC systems (IT systems) devices up to DC 0- 1000V. BIM-CH1 has insulation monitoring start and stop functions. After insulation monitoring is turned on, it can real time monitor the insulation resistance of the positive and negative poles to the ground. The monitoring results are not affected by DC voltage fluctuations and the symmetry of the insulation resistance of the positive and negative poles.

BIM-CH1 is equipped with RS485 /Modbus communication, which can remotely monitor the system status. BIM-CH1 uses two working principles for monitoring: unbalanced bridge method and balanced bridge method, allowing continuous monitoring of voltage and resistance values. Optional current sensors or temperature sensors can be configured for current and temperature measurements.
Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems
Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems
Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems
 

Feature

  1. Adaptive capacitance to ground;
  2. Widely insulation monitoring range (100V~1000VDC);
  3. Monitoring the insulation resistance for unearthed DC systems: 1KΩ~10MΩ;
  4. Measured value indication via a multi-functional LCD display;
  5. Automatic device self-test with disconnection monitoring;
  6. DC voltage reverse connection alarm function;
  7. RS485 communication, MODBUS RTU protocol;
  8. Selectable N/C or N/O relay operation;
  9. Password protection to prevent unauthorized parameter changes;
  10. Optional temperature sensor for system temperature measurement.
 

Specification

Parameter Value
Power supply 10-30VDC, Power 3w
DC voltage range 100V~1000V
DC voltage
measurement accuracy
≤2V+0.3%
Insulation resistance
measurement range
1KΩ~10MΩ
(DC System voltage:100V~1000V)
Insulation monitoring accuracy
((When :DC voltage:100V-1000V)
CY range Resistance range Accuracy
0~0.8μF ≤60kΩ ≤3kΩ
60kΩ<R≤1MΩ ≤5%
0.8μF ~3μF ≤60kΩ ≤6kΩ
60kΩ<R≤1MΩ ≤20%
Insulation resistance value
update time after turning on
After insulation monitoring is turned on, the time until the effective resistance value can be read for the first time 0.7s~2s
Insulation resistance value
update time
Switch the insulation resistance until the module can read the switched insulation resistance value. 0.5s~3s
Insulation monitoring function switching times 50*105 times
Off-line pressure test <2mA
Standard IEC 61557-8:2018
Humidity 85%
Storage temperature - 40°C ~125°C
Operating temperature - 40°C ~75°C

Application

Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems

Company Profile

 

Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems

Certifications

Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems

Our Service

Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems

FAQ

Blue Jay Bim Series Insulation Monitoring of Unearthed Power Supplies It Systems

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier